<< Back to Chemical Sampling Information

Chemical Sampling Information (CSI)
Search (use word(s)/phrase)
Table of Contents
By Name
A B C D E F G H I J K L M
N O P Q R S T U V W X Y Z

By CAS Number
Quick Links

General Description

OSHA IMIS Code Number: T111

Monitoring Methods used by OSHA

Primary Laboratory Sampling/Analytical Method (SLC1):

  • sampling media: Tared Low Ash Polyvinyl Chloride (LAPVC) filter 5 microns preceded by a 10 mm Nylon cyclone
    maximum volume: 816 Liters
    maximum flow rate: 1.7 L/min
    current analytical method: Gravimetric
    method reference: 11,12
    sampling and analytical error: 0.10
    method classification: Fully Validated
    note: Field method, do not submit sample to the Salt Lake Technical Center. If the filter is not overloaded, samples may be collected up to an 8-hour period.

** All Trademarks are the property of their respective owners.