General Description

Synonyms: Pentalin; Ethane Pentachloride

OSHA IMIS Code Number: P119

Chemical Abstracts Service (CAS) Registry Number: 76-01-7

NIOSH Registry of Toxic Effects of Chemical Substances (RTECS) Identification Number: KI6300000; 33634

Department of Transportation Regulation Number (49 CFR 172.101) and Guide: UN1669 Poison

Health Factors

Carcinogenic Classification:

International Agency for Research on Cancer (IARC): Group 3, not classifiable as to its carcinogenicity to humans
Monitoring Methods used by OSHA

Primary Laboratory Sampling/Analytical Method (SLC1):

  • sampling media: Porapak R Tube (70/35 mg sections, 50/80 mesh)
    analytical solvent: Hexane
    maximum volume: 10 Liters
    maximum flow rate: 0.2 L/min
    current analytical method: Gas Chromatography; GC/ECD
    method reference: 1 (NIOSH 2517)
    sampling and analytical error: 0.12
    method classification: Fully Validated