<< Back to Chemical Sampling Information

Chemical Sampling Information (CSI)
Search (use word(s)/phrase)
Table of Contents
By Name
A B C D E F G H I J K L M
N O P Q R S T U V W X Y Z

By CAS Number
Quick Links

General Description

OSHA IMIS Code Number: X100

Chemical Abstracts Service (CAS) Registry Number: 7782-44-7

NIOSH Registry of Toxic Effects of Chemical Substances (RTECS) Identification Number: RS2060000

Health Factors

Potential Symptoms: Cough; dizziness; sore throat; visual disturbances at very high concentrations. At 100% oxygen for more than 24 hours: symptoms above plus weakness, fatigue, pain in joints and muscles, numbness and tingling in arms and legs, palpitations, headache, nasal congestion, ear disturbances, nausea, vomiting, loss of appetite, fever and swelling of mucous membranes. On contact with liquid: freezing burns

Affected Organs: Respiratory system, CNS

Notes:

  1. OSHA does not have a PEL for oxygen. Minimum acceptable breathing air contains 19.5% oxygen (29 CFR 1910.146(b)).
  2. Strong oxidant that reacts with combustible and reducing materials, causing fire and explosion hazard.

Literature Basis:

  • International Chemical Safety Cards (WHO/IPCS/ILO): Oxygen.
  • Pohanish, R.P. (editor): Oxygen. In, Sittig's Handbook of Toxic and Hazardous Chemicals and Carcinogens, Fourth Ed., Vol. 2. Norwich, NY: Noyes Publications, William Andrew Publishing, 2002, pp. 1771-1772.

Date Last Revised: 03/02/2004

Monitoring Methods used by OSHA

On-Site Sampling Techniques/Methods:

  • device: Detector Tube
    manufacturer: Dräger
    model/type: Oxygen 5%/B, order no. 67 28081
    sampling information: 1 stroke
    upper measurement limit: 23 Vol.-%
    detection limit: approximately 2 Vol.-%
    overall uncertainty: approximately 16%
    method reference: on-site air secondary (manufacturer)

  • device: Detector Tube
    manufacturer: Dräger
    model/type: Oxygen 5%/C, order no. 81 03261
    sampling information: 1 stroke
    upper measurement limit: 23 Vol.-%
    detection limit: approximately 2 Vol.-%
    overall uncertainty: approximately 16%
    method reference: on-site air secondary (manufacturer)

  • device: Detector Tube
    manufacturer: Gastec
    model/type: 31B
    sampling information: 0.5 or 1 stroke
    upper measurement limit: 24%
    detection limit: 2%
    overall uncertainty: 8% for 6 to 24%
    method reference: on-site air secondary (manufacturer)

  • device: Detector Tube
    manufacturer: Matheson-Kitagawa
    model/type: 8014-159SA
    sampling information: 0.5 stroke
    upper measurement limit: 24%
    detection limit: approximately 2%
    overall uncertainty: unknown
    method reference: on-site air secondary (manufacturer)

  • device: Detector Tube
    manufacturer: Matheson-Kitagawa
    model/type: 8014-159SB
    sampling information: 0.5 stroke
    upper measurement limit: 24%
    detection limit: approximately 2%
    overall uncertainty: unknown
    method reference: on-site air secondary (manufacturer)

  • device: Detector Tube
    manufacturer: Matheson-Kitagawa
    model/type: 8014-159SC
    sampling information: 0.5 or 1 stroke
    upper measurement limit: 24%
    detection limit: approximately 1%
    overall uncertainty: unknown
    method reference: on-site air secondary (manufacturer)