General Description

OSHA IMIS Code Number: L150

Chemical Description and Physical Properties:

solid

Health Factors

Health Effects: Irritation-Eyes, Nose, Throat, Skin---Marked (HE14) Lung damage (HE11); CNS effects (HE7)

Monitoring Methods used by OSHA

Primary Laboratory Sampling/Analytical Method (SLC1):

  • sampling media: Mixed Cellulose Ester Filter (MCEF) 0.8 microns
    analytical solvent: Deionized Water
    maximum volume: 960 Liters
    minimum volume: 480 Liters
    maximum flow rate: 2.0 L/min
    current analytical method: Atomic Absorption Spectroscopy; AAS/Water extraction
    method reference: 2 (OSHA In-House File)
    method classification: Not Validated
    note: Submit as a separate sample. If the filter is not overloaded, samples may be collected up to an 8-hour period. When analysis of a compound is requested, an elemental analysis is performed and reported as the compound.