<< Back to Chemical Sampling Information

Chemical Sampling Information (CSI)
Search (use word(s)/phrase)
Table of Contents
By Name
A B C D E F G H I J K L M
N O P Q R S T U V W X Y Z

By CAS Number
Quick Links

General Description

OSHA IMIS Code Number: F106

Chemical Abstracts Service (CAS) Registry Number: 86-73-7

NIOSH Registry of Toxic Effects of Chemical Substances (RTECS) Identification Number: LL5670000; 36024

Health Factors

Carcinogenic Classification:

    International Agency for Research on Cancer (IARC): Group 3, not classifiable as to its carcinogenicity to humans

Monitoring Methods used by OSHA

Laboratory Sampling/Analytical Method:

  • sampling media: Glass Fiber Filter (37 mm)
    analytical solvent: Benzene
    maximum volume: 960 Liters
    maximum flow rate: 2.0 L/min
    current analytical method: High Performance Liquid Chromatography; HPLC/UV/FLU
    method reference: 2 (OSHA In-House File)
    method classification: Not Validated
    note: After sampling, transfer Glass Fiber Filter to separate scintillation vial, seal with Teflon-lined cap.

Conditions:

  • column: C18
    mobile phase: 85:15
    acetonitrile: Water
    detector wavelength: 254 nm UV (254 ex, 370 em fluor)
    detection limit:

Bulk Method:

    Limit the amount of bulk submitted to one gram or one mL.

**All Trademarks are the property of their respective owners.