OSHA IMIS Code Number: D147
Chemical Abstracts Service (CAS) Registry Number: 6656-03-7
Primary Laboratory Sampling/Analytical Method (SLC1):
- sampling media: Glass Fiber Filter (37 mm)
maximum volume: 180 Liters
maximum flow rate: 1.0 L/min
current analytical method: High Performance Liquid Chromatography; HPLC/U.
method reference: 2 (OSHA In-House File)
method classification: Not Validated
Conditions: Extract with 43% Methanol/57% water, PIC A; C18 column; Solvent program, initial - 40% methanol 60% water, PIC A, 12 min curve 10 to 75% methanol 25% water, PIC A; 1 mL/min; UV = 546, 436; DL 25 ng/inj; C/P DBA
Wipe Sampling Method:
- sampling media: Glass Fiber Filter
Bulk Method:
- For any dye analysis, a bulk sample of the dye must be sent to the Salt Lake Technical Center. Limit the amount of bulk submitted to one gram or approx. one mL.
** All Trademarks are the property of their respective owners.