Powered by GoogleTranslate

Cyclohexylamine

General Description

  • Synonyms: Aminocyclohexane; Aminohexahydrobenzene; Aniline Hexahydro; CHA; Hexahydrobenzenamine
  • OSHA IMIS Code Number: 0842
  • Chemical Abstracts Service (CAS) Registry Number: 108-91-8
  • NIOSH Registry of Toxic Effects of Chemical Substances (RTECS) Identification Number: GX0700000; 28789
  • Department of Transportation Regulation Number (49 CFR 172.101) and Emergency Response Guidebook: UN2375 129; Flammable Liquid and Corrosive
  • Chemical Description and Physical Properties:
    • molecular weight: 99.20
    • molecular formula: C6H13N

Exposure Limits

American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value (TLV): 10 ppm, 41 mg/m3 TWA; Appendix A4 (Not Classifiable as a Human Carcinogen)

National Institute for Occupational Safety and Health (NIOSH) Recommended Exposure Limit (REL): 10 ppm TWA

Health Factors

Health Effects: Irritation-Eye, Nose, Throat, Skin---Marked (HE14) Mutagen (HE2); CNS disturbances (HE7)

Monitoring Methods used by OSHA

Primary Laboratory Sampling/Analytical Method (SLC1):
  • Coated XAD-7 Tube (80/40 mg sections) Coating is 10% Phosphoric Acid.
  • analytical solvent: 50:50 Methanol: Deionized Water
  • alternate solvent: 0.88 N NH4OH in Methanol
  • maximum volume: 20 Liters
  • maximum flow rate: 0.2 L/min
  • current analytical method: Gas Chromatography; GC/FID
  • method reference: 2 (OSHA In-House File)
  • method classification: Partially Validated
  • note: The ammonium hydroxide eliminates the need for neutralization of the desorbing solution but the ammonia liberated may be an interference in the analysis.
Secondary Laboratory Sampling/Analytical Method (SAM2):
  • Detector Tube
  • company: MSA
  • part #: 92115
  • range: 5-100 ppm
  • class: Mfg
  • Detector Tube
  • company: Gastec
  • part#: 180
  • range: 1-60 ppm
  • class: Mfg

** All Trademarks are the property of their respective owners.

Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.