<< Back to Chemical Sampling Information

Chemical Sampling Information (CSI)
Search (use word(s)/phrase)
Table of Contents
By Name
A B C D E F G H I J K L M
N O P Q R S T U V W X Y Z

By CAS Number
Quick Links

General Description

OSHA IMIS Code Number: C119

Chemical Abstracts Service (CAS) Registry Number: 7440-45-1

Monitoring Methods used by OSHA

Laboratory Sampling/Analytical Method:

  • See Particulates not otherwise regulated (Respirable Fraction) O
  • sampling media: Mixed Cellulose Ester Filter (MCEF) 0.8 microns
    maximum volume: 960 Liters
    minimum volume: 480 Liters
    maximum flow rate: 2.0 L/min
    current analytical method: Atomic Absorption Spectroscopy; AAS
    method reference: 2 (OSHA ID-121)
    method classification: Not Validated
    note: Submit as separate sample. If the filter is not overloaded samples may be collected up to eight hours. An elemental analysis is performed for Cerium.

Conditions: Cerium is soluble in concentrated or dilute mineral acids.

** All Trademarks are the property of their respective owners.