    TEXT VERSION OF SLIDE:

    Title: Table 1. Predicted Distances for Compliance with FCC Limits: 0.1 Wavelength
    Type: Text Slide
    Content:

    Frequency
    (KHz)
    Transmitter Power (kW)
    50 10 5 1
    Predicted Distance for Compliance with FCC Limits (meters)
    535-740 13 7 6 3
    750-940 12 7 5 3
    950-1140 11 6 5 3
    1150-1340 10 6 5 3
    1350-1540 10 6 5 3
    1550-1705 10 6 5 3