TEXT VERSION OF SLIDE:

Title: Intentionally Working Closer Than Table A Zone

Type: Text Slide with image

Content:

Must Show:

  • Staying outside zone is infeasible
  • Infeasible to deenergize and ground.
  • All of the following are required:
    1. power line owner - sets minimum approach distance
    2. Planning meeting - minimum procedures
      • dedicated spotter
      • Elevated warning line or barricade
      • Insulating link/device
      • Nonconductive rigging
      • Range limiter (if equipped)
      • Nonconductive tag line (if used)
      • Barricades - 10 feet from equipment
      • Limit access to essential workers
      • Prohibit non-operator workers from touching above insulating link
      • Properly ground crane
      • Deactivate automatic re-energizer
      • Insulating line cover-up installed

[Includes image of crane and power lines.]

Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.