<< Return to Previous Page

Oxide Drum Filling Local Exhaust Ventilation


Oxide Drum Filling Local Exhaust Ventilation

Text Version

Oxide Drum Filling Local Exhaust Ventilation

Oxide drum with drum filling tube, plenum, perforated plate (50% open) or slotted plate (size slot for 2000 fpm), flare fill tube, and flexible tubing to fan or main with 45% take-off. A schematic view is also included.

Design Criteria:

Q = 600 cfm
Vt = 4,500 fpm
he = 1.78 VPslot + 0.25 VPduct