| 1. |
2005 - 07/07/2005 - Machine guarding and exposure to hazards from robotic laundry shuttles. |
17k |
July 7, 2005 Mr. Eric Frumin UNITE Health and Safety Department 275 Seventh Avenue, 10th Floor New York, NY 10001-6708 Dear Mr. Frumin: Thank you for your January 31, 2005 fax to the Occupational Saf...
http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=INTERPRETATIONS&p_id=25630
|
| 2. |
1996 - 09/11/1996 - Voluntary safety and health audits under the Occupational Safety and Health Act. |
31k |
September 11, 1996 Mr. Frank White Vice President Organization Resources Counselors, Inc. 1910 Sunderland Place, NW Washington, D.C. 20036 Dear Mr. White: Thank you for your letter to Secretary Reich...
http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=INTERPRETATIONS&p_id=22265
|
| 3. |
2002 - 01/29/2002 - Authorized employees must have the opportunity to verify energy isolation in group lockout/tagout |
15k |
January 29, 2002 Mr. Jack Prestwood Tampa Electric Company Polk Power Station PO Box 111 Tampa, Fl 33601 Dear Mr. Prestwood: Thank you for your June 8, 2001 facsimile to the Occupational Safety and H...
http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=INTERPRETATIONS&p_id=24005
|
| 4. |
2006 - 07/12/2006 - PSM compliance for ammonia refrigeration systems. |
52k |
July 12, 2006 Mr. E. C. Palmer, Jr. Environmental Attorney/Consultant LAMB GROUP, LLC. 330 Providence Road Athens, GA 30606 Dear Mr. Palmer: This is in response to your letter dated August 22, 2004, ...
http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=INTERPRETATIONS&p_id=25576
|
| 5. |
2012 - 11/20/2012 - Clarification of the lockout/tags-plus standard for maritime employment. |
25k |
November 20, 2012 Matthew Paxton President Shipbuilders Council of America 655 Fifteenth Street, NW Suite 225 Washington, DC 20005 Dear Mr. Paxton, In response to your concerns regarding the recently...
http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=INTERPRETATIONS&p_id=28481
|
| 6. |
2006 - 07/20/2006 - Clarification of supervisor accessibility to individual field-lock keys in a group lock box under 1910.269. |
16k |
This letter constitutes OSHA's interpretation only of the requirements discussed and may not be applicable to any situation not delineated within the original correspondence. July 20, 2006 Mr. Wi...
http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=INTERPRETATIONS&p_id=25948
|
| 7. |
2006 - 05/09/2006 - Use of additional lock on a conveyor and baler system exceeds one lockout device. |
12k |
This letter constitutes OSHA's interpretation only of the requirements discussed and may not be applicable to any situation not delineated within the original correspondence. May 9, 2006 Mr. Kevi...
http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=INTERPRETATIONS&p_id=25370
|
| 8. |
2005 - 12/02/2005 - Clarification of "potential atmospheric hazard" when reclassifying a PRCS as a non-permit required confined space. |
16k |
This letter constitutes OSHA's interpretation only of the requirements discussed and may not be applicable to any situation not delineated within the original correspondence. December 2, 2005 Ms....
http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=INTERPRETATIONS&p_id=25170
|
| 9. |
2001 - 06/05/2001 - Use of Electro Sensitive Protection Equipment as point of operation guarding devices. |
19k |
This letter constitues OSHA's interpretation only of the requirements discussed and may not be applicable to any situation not delineated within the original correspondence. June 5, 2001 Mr. Robert T...
http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=INTERPRETATIONS&p_id=23980
|
| 10. |
2000 - 02/28/2000 - Removal of lockout devices by persons other than those who applied them. |
15k |
February 28, 2000 Ms. Gretchen R. Busch Project Manager The Resource Effectiveness Development Group P.O. Box 247 Reynoldsburg, OH 43068 Dear Ms. Busch: Thank you for your July 10, 1999 letter to the...
http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=INTERPRETATIONS&p_id=23287
|