| 1. |
2001 - 04/10/2001 - Requirements of Interim Fall Protection Compliance Guidelines for Residential Construction for guardrails and fall protection during roofing work. |
17k |
OSHA requirements are set by statute, standards and regulations. Our interpretation letters explain these requirements and how they apply to particular circumstances, but they cannot create additiona...
http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=INTERPRETATIONS&p_id=24308
|
| 2. |
1996 - 07/23/1996 - Enforcement of the fall protection standard and fall protection options. |
15k |
July 23, 1996 Dr. J. Nigel Ellis President Dynamic Scientific Controls P.O. Box 445 Wilmington, DE 19899-0445 Dear Dr. Ellis: This is in response to your May 6 letter addressed to Joseph A. Dear, Ass...
http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=INTERPRETATIONS&p_id=22223
|
| 3. |
1995 - 05/09/1995 - Applicability of fall protection requirements/fall protection for waste collection and landfill activities. |
15k |
May 9, 1995 Association Counsel Suite 300 Environmental Industry Associations 4301 Connecticut Avenue, N.W. Washington, D.C. 20008 Dear Mr. Moskowitz: This is in response to your letter of February 2...
http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=INTERPRETATIONS&p_id=21797
|
| 4. |
2000 - 08/14/2000 - Fall protection for various lift-devices; restraint, positioning, fall arrest and rescue requirements; maintenance vs. construction examples. |
21k |
August 14, 2000 Mr. Charles E. Hill Chairman, National Telecommunications Safety Panel Southwestern Bell Telephone Company St. Louis, Missouri 63101 Dear Mr. Hill: This is in response to your letter ...
http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=INTERPRETATIONS&p_id=24110
|
| 5. |
1999 - 08/30/1999 - OSHA requires fall protection for elevator work when a fall hazard is present. |
12k |
August 30, 1999 Mr. Stephen Mallinger Office of Compliance Room LA 200 John Adams Building 110 Second Street S.E. Washington, D.C. 20540-1999 Dear Mr. Mallinger: Thank you for your August 2, 1999 let...
http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=INTERPRETATIONS&p_id=22782
|
| 6. |
2012 - 12/05/2012 - Clarification concerning fall protection and vertical walled trenches with depth of 6 feet or greater and use of controlled access zones. |
14k |
OSHA requirements are set by statute, standards and regulations. Our interpretation letters explain these requirements and how they apply to particular circumstances, but they cannot create additiona...
http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=INTERPRETATIONS&p_id=24371
|
| 7. |
2012 - 04/20/2012 - Clarification on the use of safety monitors as a method of fall protection on a low-slope roof. |
15k |
April 20, 2012 Andrew Wilson, P.E. CVM PO Box 398 Oaks, Pennsylvania, 19456 Dear Mr. Wilson: Thank you for your February 1, 2012, letter to the Occupational Safety and Health Administration (OSHA). B...
http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=INTERPRETATIONS&p_id=28259
|
| 8. |
2011 - 05/25/2011 - Residential Contruction; 1926.501(b)(3), fall protection or metal stud walls around stairwells. |
15k |
No Description Given....
http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=INTERPRETATIONS&p_id=28058
|
| 9. |
2011 - 04/22/2011 - Distance at which fall protection is required for steel erection activities. |
14k |
April 22, 2011 Frank Baxter Mid-Atlantic Construction Safety Council 1717 Arch Street Suite 3370 Philadelphia, PA 19103 Dear Mr. Baxter: Thank you for your September 28, 2008 letter to the Occupation...
http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=INTERPRETATIONS&p_id=28241
|
| 10. |
2010 - 03/02/2010 - Fall protection requirements for employees working on an elevator car frame. |
16k |
No Description Given....
http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=INTERPRETATIONS&p_id=27311
|