| Standard Number: | 1910.23; 1910.23(c) |
|
February 14, 2006 Mr. Todd B. Logsdon Greenebaum, Doll, & McDonald PLLC 3500 National City Tower 101 South Fifth Street Louisville, KY 40202-3197 Dear Mr. Logsdon: Thank you for your March 31, 2005, letter to the Occupational Safety and Health Administration's (OSHA's) Directorate of Enforcement Programs (DEP). This letter constitutes OSHA's interpretation only of the requirements discussed and may not be applicable to any questions not delineated within your original correspondence. You are requesting clarification, for your client, on whether the proposed procedures would meet the intent for an alternative fall protection program when guardrails are infeasible to install. Your paraphrased scenario, question, and our responses are provided below. Scenario: Employees gain access to rooftops via roof hatches, interior stairwells that are located in the center of rooftops, and at the rooftops' edges via exterior fixed ladders, staircases, and portable extension ladders to perform post-construction. The rooftop's surface ranges from 300,000 to 1,000,000 square feet with different configurations and has a 4:12 slope. Employees are never closer than 15 feet to the roof's edge. Question: Would a painted, large red stripe 15 feet away from the roof's edge designating a work zone, plus the following conditions be an acceptable alternative for guardrails?
Proposed 1910.28(d)(1) would address "work...of a temporary nature, such as maintenance on roof top equipment." For such work, "[e]mployers may establish designated areas which comply with the provisions of this paragraph as an alternative to installing guardrails, where employers demonstrate that employees within the designated areas are not exposed to fall hazards." Under the proposed standard, however, a painted line cannot be used to demarcate the designated area. A designated area must be surrounded by a rope, wire or chain and supporting stanchions. For your convenience in reviewing the proposed standard in its entirely, we are enclosing a copy of the 2003 Federal Register reprint. If an employer follows the requirements for designated areas in lieu of conventional guardrails, OSHA would consider it to be a de minimis violation. De minimis violations are violations of standards which have no direct or immediate relationship to safety or health. Under the de minimis policy, an employer may comply with a proposed standard or amendment or a consensus standard, rather than with the standard in effect at the time of the inspection, only if the employer's action clearly provides equal or greater employee protection or the employer complies with a written interpretation issued by the OSHA Regional or National Office. With de minimis violations, OSHA does not issue citations, or require abatement. As you may know, the State of Kentucky administers its own occupational safety and health program under a plan approved and monitored by Federal OSHA. States are required to have regulations that are, at least as effective as the federal standards, although they may be more stringent. In order to obtain Kentucky's policy on this issue, you may direct your inquiry to: Philip J. Anderson, Commissioner Sincerely, Richard E. Fairfax, Director Directorate of Enforcement Programs Enclosures |
|
|

Newsletter
RSS Feeds
Print This Page
Text Size