| Standard Number: | 1926.760(a)(1); 1926.760(a)(2); 1926.760(a)(3) |
July 21, 2003 Mr. Jerry Breneman 16001 Park Ten Place Houston, TX 77084 Re: In steel erection, may a guardrail system other than a safety cable be used to meet the requirement for a perimeter safety cable under Part 1926 Subpart R? Dear Mr. Breneman: This is in response to your E-correspondence of September 17, 2002, to the Occupational Safety and Health Administration (OSHA). We apologize for the delay in providing a response. We have paraphrased your question as follows: Question: The steel erection standard requires perimeter safety cables on multi-story structures. Is it permissible to use other types of guardrail systems (such as wooden guardrails) to meet this requirement? Answer: Section 1926.760(a)(1) states: Except as provided in paragraph (a)(3) of this section, each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6m) above a lower level shall be protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems or fall restraint systems.Section 1926.760(a)(2) further requires that: On multi-story structures, perimeter safety cables shall be installed at the final interior and exterior perimeters of the floors as soon as the metal decking has been installed.Section 1926.760(a)(2) was promulgated in conjunction with the requirement that perimeter columns have holes or attachments to facilitate the speedy erection of an effective and durable fall protection system. In the preamble to the Final Rule, OSHA explained that the Steel Erection Negotiated Rulemaking Advisory Committee (SENRAC) believed that the relative ease with which safety cables can be erected, especially where columns have pre-installed holes or attachments, presents several safety advantages (66 FR 5228-5229 and 5245, Jan. 18, 2001). Specifically, this system:
Sincerely, Russell B. Swanson, Director Directorate of Construction |
|
|

Newsletter
RSS Feeds
Print This Page
Text Size