|
October 21, 1999
Mr. Raymond R. Peterson
President
VISTA
810 Krift Avenue, P. O. Box 247
Burlington, Wisconsin 53105-0247
Re: Powered Industrial Truck Training: §§1910.178(l) and 1926.602(a)(1) and (d)
Dear Mr. Peterson:
This is in response to your letters of April 2, and April 21, 1999, to the Occupational Safety and
Health Administration (OSHA) regarding the new requirements for powered industrial truck
operator training in §1910.178(l) (under §1926.602(d), those requirements are
applicable to employers engaged in construction).
In your April 2 letter you ask if the requirements apply to heavy equipment ordinarily used for earth
moving work such as skid-steer loaders, articulated wheel loaders or backhoe loaders when
equipped with forklift attachments and used primarily for material handling. We assume that your
question relates to the use of these machines in construction.
Scope of the Powered Industrial Truck standard
Section 1910.178(a) states that the Powered Industrial Truck standard does not apply "to vehicles
intended primarily for earth moving..." When OSHA recently added the new training requirements
(§1910.178(l)) to this standard, we reiterated that the standard does not apply to earth
moving equipment even when used with a forklift attachment. In the preamble to the new training
requirements (volume 63 of the Federal Register on page 66,255) we stated:
The final rule does not, however, apply to earth moving equipment or vehicles used for over-the-road hauling.
Three commenters suggested that OSHA clarify the scope of these training requirements (Exs. 7-25, 7-37, and 11-
2). These commenters stated that the discussion of the scope issue in the proposal's preamble could mislead
employers into thinking that earth moving equipment and over-the-road vehicles were included in the scope
because these vehicles can lift and move material. OSHA agrees that these vehicles are not powered industrial
trucks for the purposes of this rule. Therefore, equipment that was designed to move earth but has been
modified to accept forks is not covered by this final rule. [Emphasis added].
So, the standard does not apply to earthmoving equipment even if it has a fork lift attachment and is
being used for material handling.
Front end and backhoe loaders are not covered by the standard
Since front-end and backhoe loaders are designed to move earth, they are not covered by the
standard. Also, in the rule's preamble (Federal Register pages 66,254-5), OSHA stated that the
scope of the standard is the same as the scope of the American National Standards Institute (ANSI)
B56.1-1969 standard and includes equipment covered by several American Society of Mechanical
Engineers (ASME) standards - including ASME B56.6 (Rough Terrain Forklift Trucks). The
ASME B56.6 standard excludes "loaders...even though their
buckets and blades are replaced with forks...." (Emphasis added.)
Some skid-steer equipment is covered by the standard
"Skid-steer" refers to a steering system that allows the wheels on opposite sides of a machine to turn
independently of each other, which gives the vehicle the ability to make a complete rotation within its
own length. Skid-steer equipment that is earthmoving equipment is not covered by the standard.
However, if it is not earthmoving equipment, it is covered. For example, in Appendix B to ASME
B56.6-1992, under the definition of the term "truck, rough terrain forklift" there is an illustration of a
vertical mast skid-steer forklift (Figure B4). That equipment, which is within the scope of ASME
B56.6, is covered by the new training requirement.
Recommended training
While loaders, skid-steer loaders, and similar equipment with forklift attachments are not covered
under §1926.602(d), we recommend that employers who use these attachments provide the
training described in the standard. In the preamble (in the first column on Federal Register
page 66,242), OSHA stated that powered industrial trucks can be equipped with, or can
be modified to accept, attachments that permit the truck to move odd-shaped material or carry out
tasks that may not have been envisioned when the truck was designed and manufactured. Effective
operator training for trucks with specialized attachments would include instruction on the safe
conduct of those operations so that the operator knows and understands the restrictions and
limitations of the vehicle in those situations. Remember that, with respect to trucks that are beyond
the scope of §1926.602(d), the requirements of §1926.21 continue to apply. Under
§1926.21, employers are required to "instruct each employee in the recognition and
avoidance of unsafe conditions...."
We note that in February 1998, the National Institute of Occupational Safety and Health (NIOSH)
issued Alert 98-117, "Preventing Injuries and Deaths from Skid-Steer Loaders."
NIOSH stated that they found a significant number of fatalities involving skid-steer loaders,
pointing out that these vehicles put workers at risk of rollover and run-over incidents,
along with hazards stemming from required entry and exit from the front over the bucket and
hazards from the compact size of the machine, which places the operator close to the zone
of movement for the lift arms.
Extent to which training must be specific to particular makes and
models of equipment
In your April 21 letter, you ask if contractors must train their employees on each style, make and
model of forklift that they have, or if they may train employees on an entire class of machine. You
give the example of an employer having multiple "Telescopic Boom Rough-Terrain" forklifts that are
made by different manufactures. You want to know if the employer must train employees on
manufacturer-specific forklifts, or whether it is acceptable to provide training generalized to the type
of forklift.
Operators who have successfully completed training and evaluation on a specific type of truck would
not normally need additional training when they are assigned to operate the same type of truck made
by a different manufacturer. However, additional training would be required if there are significant
differences that could affect the safe use of the truck.
If you require any further assistance, please do not hesitate to contact us again by writing to:
Directorate of Construction - OSHA Office of Construction Standard and Compliance Assistance,
Room N3468, 200 Constitution Avenue N.W., Washington D.C. 20210.
Sincerely,
Russell B. Swanson, Director
Directorate of Construction
|