| www.OSHA.gov | |
|
Standard Interpretations
08/26/1996 - Clarification of Asbestos standard. |
|
|
| Standard Number: | 1926.1101 |
|
August 26, 1996
Mr. Edward M. Monaco, President Dear Mr. Monaco: This is in response to your letter dated July 16, 1996, to William Q. Wiehrdt in the Occupational Safety and Health Administration's (OSHA) Chicago Regional Office requesting clarification of OSHA's Asbestos standard (29 CFR 1926.1101) for the construction industry. You requested that OSHA specify the class of asbestos work (Class I, II, III, or IV) to which the removal of asbestos-containing paint would belong. The removal of asbestos-containing paint of ordinary film thickness is Class II asbestos work. The removal of thick-film, textured, asbestos-containing paint would be Class I work if the material resembles troweled or sprayed on surfacing material. We appreciate the opportunity to clarify this matter for you. If you have further questions please contact my office at (202) 219-8036.
Sincerely,
|
|
|
| www.osha.gov | www.dol.gov | |
Contact Us | Freedom of Information Act | Customer Survey Privacy and Security Statement | Disclaimers |
||
| Occupational Safety & Health Administration 200 Constitution Avenue, NW Washington, DC 20210 |
||