|
|
| Standard Number: | 1910.134(g); 1910.120; 1910.156 |
May 1, 1995
The agency has recently received a number of requests for interpretation of the Occupational Safety and Health Administration (OSHA) requirements for workers who are actively conducting operations in atmospheres that are immediately dangerous to life and health (IDLH). The specific question posed is whether OSHA regulations mandate the minimum number of workers required to be involved in operations under IDLH or potential IDLH conditions. The purpose of this memorandum is to clarify requirements under all of the applicable standards which have a bearing on this question, namely: Hazardous Waste Operations and Emergency Response (HAZWOPER), 29 CFR 1910.120; Respiratory Protection, 29 CFR 1910.134; Fire Brigades, 29 CFR 1910.156; and Section 5(a)(1) of the Occupational Safety and Health Act of 1970. It is intended to apply to operations where IDLH conditions exist or potentially exist in the following situations:
This memorandum does not address entry into a confined space containing an IDLH atmosphere. That subject is addressed in the Permit Required Confined Space standard, 29 CFR 1910.146, and is discussed in the compliance directive on that standard. CLARIFICATION OF 1910.120: Attached for your reference is a copy of an August 15, 1994, letter to Ms. Peg Seminario of the AFL-CIO that provides OSHA's current interpretation of the HAZWOPER standard as it relates to IDLH operations. The letter specifically addresses the HAZWOPER requirement for workers who are engaged in remedial operations as well as in emergency response operations in atmospheres which are or may be IDLH and who utilize self-contained breathing apparatus (SCBA) for the control of inhalation hazard(s). The HAZWOPER standard addresses three categories of employees: workers at hazardous waste sites (paragraphs b-o), workers at Treatment, Storage, and Disposal facilities (paragraph p) and workers in workplace situations where they face an actual or potential emergency from the release of hazardous substances (paragraph q). Fire fighters are often involved in emergency response operations when serving as members of an organized HAZMAT team, and as such, would be covered by the HAZWOPER standard. Paragraph 1910.120(q)(3)(v) of HAZWOPER requires that "operations in hazardous areas (emphasis added) shall be performed using the buddy system in groups of two or more." In addition, paragraph 1910.120(q)(3)(vi) states that "back up personnel shall stand by with equipment ready to provide assistance or rescue." This section means that as a minimum the buddy system must be used within the hazardous area (entry by at least two persons) and at least two additional personnel shall stand by outside the hazardous area. Thus, there must be at least four individuals at the site. One of the two individuals outside the hazard area can be assigned to another task, provided that the second assignment does not interfere with the performance of the standby role. Regarding the use of buddy systems, OSHA understands the HAZWOPER standard to mean the following: a buddy shall be assigned who is able to: (1) provide the partner with assistance; (2) observe the partner for signs of chemical, heat, or other hazardous exposure; (3) periodically check the integrity of the partner's personal protective equipment/clothing; and (4) if emergency help is needed, notify the appropriate individual (i.e., the Command Post Supervisor, the On-Scene Incident Commander). The standard defines a "buddy system" and "IDLH" below as: Buddy system means a system of organizing employees into workgroups in such a manner that each employee of the work group is designated to be observed by at least one other employee in the work group. The purpose of the buddy system is to provide rapid assistance to employees in the event of an emergency.Please refer to OSHA Instruction CPL 2-2.59, "Inspection Procedures for the Hazardous Waste Operations and Emergency Response Standard, 29 CFR 1910.120, paragraph (q): Emergency Response to Hazardous Substance Releases," for further compliance guidance and information on paragraph (q). CLARIFICATION OF 1910.134: This document was edited on 04/01/99 to strike information that no longer reflects current OSHA policy.] CLARIFICATION OF 1910.156: The Fire Brigade standard, 29 CFR 1910.156, contains mandatory requirements for fire fighting units. The standard covers only emergency operations involving interior structural fire fighting. Because fire brigades vary in type, function and size, the OSHA requirements are performance oriented to provide enough flexibility for the employer to organize a fire brigade which best reflects the needs of the workplace. In 29 CFR 1910.155, "Scope, application and definitions applicable to this subpart" (i.e., Subpart L) defines interior structural fire fighting as: "the physical activity of fire suppression rescue or both inside of buildings or enclosed structures which are involved in a fire situation beyond the incipient stage." Enclosed structure means: "a structure with a roof or ceiling and at least two walls which may present fire hazards to employees, such as accumulations of smoke, toxic gases and heat, similar to those found in buildings." An incipient stage fire is defined by the regulation as: "a fire which is in the initial or beginning stage and which can be controlled or extinguished by portable fire extinguishers, Class II standpipe or small hose systems without the need for protective clothing or breathing apparatus. It is universally recognized that conditions present during an advanced Interior structural fire create an IDLH. The Fire Brigade standard does not directly address the minimum number of fire fighters required when engaged in operations presenting an IDLH atmosphere. Regarding the use or SCBA's in IDLH atmospheres, paragraph 1910.156(f)(1)(i) does refer to the Respiratory protection standard, 1910.134, which has been discussed earlier. APPLICATION OF RELEVANT NFPA STANDARDS Two national consensus standards are relevant to the issue of fire fighter safety and provide further detailed requirements for the industry. The first standard is NFPA 1500-1992, entitled Fire Department Occupational Safety and Health Program. It has an interim amendment (attached) that states at 6-4.1.1: "At least four members shall be assembled before initiating interior fire fighting operations at a working structural fire." Working structural fire is defined in section 1-5 as follows: Any fire that requires the use of a 1 and 1/2 inch or larger fire attack hose line and that also requires tee use of self-contained breathing apparatus for members entering the hazardous area." in reality the term means the same thing as the OSHA term interior structural fire fighting. Consequently, four persons, two in and two out, each with protective clothing and respiratory protection are essential for the safety of those performing this work inside a structure. In addition to this interim amendment, NFPA 1500 has other relevant criteria found in requirements 6-4.3 and 6-4.4. In 6-4.3 the standard requires members operating inside hazardous areas during emergency incidents to operate in teams of two or more. Team members operating within hazardous areas shall be in communication with each other through visual, audible, physical, safety guiderope, electronic means or other means to coordinate their activities. Section 6-4.4 further requires that in the initial stages of an incident, where only one team is operating in the hazardous area, at least one additional member shall be assigned to stand by outside the hazardous area where the team is operating. This standby member shall be responsible for maintaining constant awareness of those working in the hazardous area, their location, time of entry, functions, and identity. A second person (the incident commander) outside the hazard area is specified by Section 6-1 of the NFPA 1500. In summary, NFPA 1500, requires four fire fighters on the scene before performing interior structural fire fighting operations, and, when fire fighters or other personnel actually perform interior attack, they are to enter the hazardous area using teams of at least two members. The second applicable NFPA standard is NFPA 600-1992, Standard on Industrial Fire Brigades (attached) Chapter 5 of this standard entitled, "Fire Brigades That Perform Interior Structural Fire Fighting Only," paragraph 5-3.5, specifies requirements for the number of members to be involved at the scene. Requirements in 5-3.5 are almost exactly the same as those in Sections 6-4.3 and 6-4.4 of NFPA 1500. Additionally, NFPA 600 and NFPA 1500 both require a fire officer to be the incident manager. This NFPA requirement, along with the other requirements discussed above, results in a minimum of four members on the scene before beginning to fight interior structural fires: two inside as a team, operating in the hazardous area; two outside the hazardous area, where one is standing by and another may be performing another function, such as managing the incident, as long as its performance does not interfere with the second outside person's ability to assist in the event of an emergency. This standard does not address the number of persons necessary to staff a fire apparatus leaving a station before on-scene evaluation has occurred. That is a matter to be determined by each local fire fighting unit. APPLICATION OF THE GENERAL DUTY CLAUSE Occupational exposure to fire is a well-recognized serious hazard and feasible abatement methods exist. Therefore, application of Section 5(a)(1) may be warranted in some circumstances. Any citation or Section 5(a)(1) must meet the requirements outlined in the Field Inspection Reference Manual (FIRM), Chapter III, and may be issued where there is a hazard which cannot be abated by compliance with a specific OSHA standard. Because OSHA's Fire Brigade standard does not directly specify the number of fire fighters who can safely perform certain fire fighting operations, the NFPA national consensus standards serve as guidance as to what is generally recognized as hazardous in the industry. The two NFPA standards referred to above explicitly address the number of persons to be involved when performing interior structural fire fighting operations. The requirements contained in these NFPA standards do not apply to exterior fire fighting or to other fire fighting activities not involving IDLH conditions. Therefore, a citation for violation of the General Duty Clause shall be issued when it is documented that only one person conducted interior structural fire fighting operations or when less than two persons were standing by when interior structural fire fighting operations were being conducted. A Section 5(a)(1) citation may not be issued for incipient stage interior fires or for exterior fire fighting operations conducted during advanced interior structural fires. STATE PLANS Regional Administrators shall explain the content of this memorandum to the State designees as requested. States are strongly encouraged to adopt an identical or at least as effective interpretation of the standards. As indicated in STP 2-2.8B, Fire Protection, because of the unique nature of fire fighting employment in the public sector, a State may develop alternate standards for State and local government employees as long as the program provides protection equivalent to that provided private sector employees. If the State develops a separate public sector standard, it must be submitted within 30 days of promulgation in accordance with STP 2-1.117. Federal OSHA does not have direct jurisdiction over State and local government employees. However, the Occupational Safety and Health Act allows States to administer their own occupational safety and health programs under plans approved and monitored by Federal OSHA. States with approved occupational safety and health State plans must adopt standards which are at least as effective as Federal OSHA standards and must provide coverage for State and local government employees as effective as that provided to private sector employees. (In states without OSHA approved plans, the Federal workplace protection provided to public sector employees would be under the Environmental Protection Agency hazardous waste operations (HAZWOPER) regulation (40 CFR Part 311); States may also enforce their own laws and regulations covering the public sector. This guidance supersedes any previously provided on the issue. Should you have any questions or comments, please contact Tom Galassi at (202) 219-8036. Attachments SUMMARY REQUIREMENTS FOR RESPONSE TO IDLH OR POTENTIAL IDLH ATMOSPHERES USING SELF-CONTAINED BREATHING APPARATUS
|
|
|

Newsletter
RSS Feeds
Print This Page
Text Size
