| Standard Number: | 1926.95 |
|
August 22, 1994 MEMORANDUM FOR: CINDY A. COE
THROUGH: JOHN B. MILES Director Directorate of Compliance Programs FROM: ROY F. GURNHAM, Director Office of Construction and Maritime Compliance Assistance SUBJECT: Request for Review of Potential 1926.95(a) Citation for Fall Protection in Steel Erection We have reviewed your request to issue a willful citation to Miller Construction Company for failure to provide fall protection during bridge construction. We concur with your request to issue a citation under 1926.95(a). The 1926.95(a) citation which you propose to issue, however, would have to be based on a hazard other than drowning since drowning hazards are addressed by other standards (also proposed for citation). Hypothermia does not seem a likely hazard under the facts as we understand them. If the water temperature was 50 to 60 degrees Fahrenheit, a worker would probably be pulled from the water well before a hypothermia danger would arise. The most likely hazard, therefore, would be an impact hazard. The object would be to show the possibility of injury in the event of a fall and that a reasonable person would recognize this possibility and the need to protect against it. If the river was very shallow in places beneath the work areas, the likelihood of injuries as a result of stiking the river bed can probably be established although you may need expert testimony should the citation be contested and litigated. If you have any further questions please contact me (at extension 150) or Mr. Dale Cavanaugh (at extension 149) of my staff at 202/219-8136. June 23, 1994 MEMORANDUM FOR: JOHN MILES, JR., Director
THROUGH: JIMMY ROBERTS, Acting Director Office of Field Programs FROM: CINDY A. COE Acting Regional Administrator SUBJECT: Request for "Egregious" Information This is in response to your memorandum concerning the above listed subject. The status report for this week is negative. June 24, 1994 MEMORANDUM FOR: JOHN B. MILES, JR., Director
ATTENTION: ROY GURNHAM Office of Construction & Maritime Assistance FROM: CINDY A. COE Acting Regional Administrator SUBJECT: Potential Citation-- 29CFR 1926.95(a) Fall Protection Less than 25 feet Miller Construction Company Inspection #10877119 In accordance with the requirements of the February 22, 1994, memorandum from James W. Stanley, Deputy Assistant Secretary, enclosed is a proposed 1926.95(a) willful citation for employees, of the Miller Construction Company, who were exposed to falls from a bridge of approximately 15 feet to the Sugar River in Newport, New Hampshire. The Concord Area Office is proposing to issue three citations as listed below: Citation #1 - Serious Item #1 29CFR 1926.106(c) $ 1,000 Item #2 29CFR 1926.106(d) $ 1,000 Citation #2 - Willful Item #1 29CFR 1926.95(a) $ 49,000 Note: This is the item for which we request your review as required by the memorandum from James W. Stanley dated February 22, 1994. Item #2 29CFR 1926.106(a) $ 49,000 Citation #3 - Repeat Item #1 29CFR 1926.1052(c)(1) $ 1,600
If you have any questions, please contact Robert B. Hooper, Assistant Regional Administrator for Federal-State Operations, at (617) 565-7164, extension 120. Attachment |
|
|

Newsletter
RSS Feeds
Print This Page
Text Size