August 11, 1987
MEMORANDUM FOR: LINDA R. ANKU
Regional Administrator
FROM: LEO CAREY, Director
Directorate of Field Operations
SUBJECT: Interpretation and Applicability of the requirements of
29 CFR 1926.450(a)(4) and (a)(5) to access ladder for
scaffolds
A portable metal ladder meeting the requirements of 29 CFR 1926.450(a)(4)
could be adequately attached to the outside of a tubular metal scaffold to
provide safe access and egress to a work platform located 100 feet above the
ground at the present time. The ladder would have to be positioned so that
its use will not have the tendency to tip the scaffold. Cages, rest
platforms or ladder safety device would not be required for employees
ascending or descending the ladder. The enforcement of 29 1926.450(a)(5)
would be inappropriate for a metal tubular scaffold.
With regard to other types of ladders, 29 CFR 1926.451(a)(13) in our general
requirements for scaffolds requires only that an access ladder or equivalent
safe access shall be provided. In view of the various rung spacings of
ladder end scaffolds, which have been designed and manufactured over
the past 30 years specifically to provide safe access to scaffolds, 29 CFR
1926.451(a)(13) should be liberally interpreted to permit the use of those
ladder systems (both portable ladders and ladders built into the scaffold
frame) which have a maximum rung spacing between rungs of 16-1/2 inches. Non
uniform rung spacing caused by joining end frames together is allowed
provided the resulting spacing does not exceed 16-1/2 inches. In no case
would the requirements of 29 CFR 1926.450(a)(5) for fixed ladders apply in
this situation.
On November 25, 1986 the Occupational Safety and Health Administration
(OSHA) proposed to revise the Construction Industry Safety Standards
addressing scaffolds. The proposal when finalized, hopefully, later this
year will probably require hook-on and attachable ladders to be provided with
rest platforms at 20 feet maximum vertical intervals for attached ladders.
In addition hook-on and attachable ladders will probably re required to be
specifically designed for use with manufactured types of scaffolds.
|