| Standard Number: | 1926.451 |
| Status: | Archived |

| NOTICE: This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only. |
|
October 3, 1985
Mr. John Rectenwald Dear Mr. Rectenwald: Mr. Richard B. Starrak, President George McQueston Company, Inc., located in Iron Horse Park, North Billerica, Massachusetts, requested that this office write to you concerning the Occupational Safety and Health Administration's (OSHA) requirements for scaffold plank. 29 CFR 1926.451(a)(10) of our Construction Industry standards requires all planking to be Scaffold Grades, or equivalent, as recognized by approved grading rules for the species of wood used. The maximum permissible spans for 2x10 inch or wider planks shall be as shown in the following table.
_________________________________________________________________
Full thickness Nominal thickness
undressed lumber lumber(1)
_________________________________________________________________
Working load (p.s.f.) 25 50 75 25 50
Permissible span (ft.) 10 8 6 8 6
_________________________________________________________________
(1) Nominal thickness lumber not recommended for heavy duty use.
It appears, based on a copy of a West Coast Lumber Inspection Bureau inspection certificate included with Mr. Starrak's letter to us that 2"x10" selected structural scaffold plank used in conformance with the spans allowed in Table L-3 would satisfy our planking standards. If we can be of further assistance, please let us know.
Sincerely,
|

| NOTICE: This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only. |
|
|