| Standard Number: | 1910.151(c) |
|
August 6, 1982
Mr. Terrill McGee Dear Mr. McGee: This is in response to your letter of July 8, 1982, petitioning for a change in the Occupational Safety and Health Administration (OSHA) standards to permit the use of readily available eyewash equipment, in some situations, as a substitute for using protection, as well as your recommendations for expanded requirements covering the location and accessibility of eyewash equipment. I would be interested in receiving copies of the research you mentioned which seemed to indicate that protective eyewear and face shields cause eye problems, irritation and headaches. My office is aware of isolated complaints, but does not have research material indicating this to be a problem. In fact, the research material which we possess indicates protective eyewear to have optical qualities of an acceptable level (see pages 124-177 of enclosed report). Additionally, overall optical characteristics of protective eyewear exceed those of prescription eyewear. Regarding your suggestion of substituting portable eyewash equipment for eye protection, we do not view this as equivalent protection. The purpose of the protective eyewear is to prevent the accident, whereas the purpose of eyewash facilities is to minimize the injury should the first line of defense fail to do the job. Your suggestions relative to better defining the requirements for eyewash facilities seem appropriate. I am providing a copy of your letter to Dr. Leonard Vance, Director, Directorate of Health Standards for consideration by his staff who have responsibility for Section 1910.151.
Sincerely,
|
|
|

Newsletter
RSS Feeds
Print This Page
Text Size