| Standard Number: | 1910.23 |
|
February 4, 1982
Lawrence R. Stafford, P.E. Dear Mr. Stafford: This is in response to the question raised in your letter of January 20, 1982, concerning a tip-up rigid guardrail system. A tip-up guardrail system 3'-6" high, with the hinged base located approximately six inches inboard from an eight inch high parapet, placing the window cleaner approximately five feet inboard from the roof edge when raising the guardrail sections, appear to comply with the intent of 29 CFR 1910.23(c). However, the anchoring of posts and framing of members for railing of all types must be of such construction that the completed structure will be capable of withstanding a load of at least 200 pounds applied in any direction at any point on the top rail. If we may be of further assistance, please call or write.
Sincerely,
|
|
|