| Standard Number: | 1910.181(j)(2)(ii) |
|
March 8, 1976
Mr. Ken Jensen Dear Mr. Jensen: This is in response to your letter requesting clarification of the OSHA requirement for safety latches on lifting hooks. The requirement for safety latches (AKA throat latches) is only specified in OSHA 1910.181(j)(2)(ii), which states that "Safety latch type hooks shall be used wherever possible." OSHA compliance officers may use the OSHA general duty clause identified as paragraph 5(a)(1) of the Williams-Steiger Act whenever a hazard is created by a hoisting operation where the hoist hook is not provided with a throat latch. The compliance officer may then support the 5(a)(1) citation by calling attention to 1910.181.(j)(2)(ii). A second alternative would be to cite the general duty clause 5(a)(1) and support it with the industry practice where the use of safety or throat latches is fairly common. Please feel free to contact us if there are further questions about OSHA. Sincerely,
Alfred Barden |
|
|