| Standard Number: | 1910.217(b)(13) |
|
August 11, 1975
MEMORANDUM TO: JOSEPH A. REIDINGER
ASSISTANT REGIONAL DIRECTOR/OSH
SUBJECT: 29 CFR 1910.21(b)(13), Simple Test: definition of
This memorandum is in response to your letter dated June 20, 1975, requesting concurrence with your interpretation to Mr. Jerry L. Addy, Commissioner, Iowa Bureau of Labor, Des Moines, Iowa, concerning the subject definition. In your interpretation of "simple test" to Mr. Addy, you state that it, "would be any action that the employer can take to either deactivate the control system or to create a failure in some part of the control system, and then demonstrate, (1) that normal press stopping has not be affected and, (2) the initiation of a successive stroke is not possible until the purposely introduced test failure has been corrected." This is a comprehensive definition and any attempt to elaborate or expand on this definition would result in setting forth procedures for all machines that may not always be applicable. Therefore, the intent of this standard is to allow the employer to establish his own testing procedures that will satisfy these requirements. Sincerely,
Barry J. White |
|
|