|
|
| Standard Number: | 1910.27(d)(1) |
|
September 4, 1974
Mr. Thomas L. Cairns Dear Mr. Cairns: I have received your request concerning 29 CFR 1910.27(d) in reference to the special requirements of cages on fixed ladders, and offer the following. The "railing ladder guard" in question does not meet the requirements of the OSHA standards. The term "equivalent construction" as used in 29 CFR 1910.27(d)(1)(i) refers to the strength and size of the material and the method of fastening devices used in the fabrication of cages. To further substantiate this, 29 CFR 1910.27(d)(1)(ii) requires cages be provided on ladders of more than twenty (20) feet to a maximum unbroken length of thirty (30) feet. It also requires dimensions of the cages be in conformance with those illustrated in Figures D-8 and D-9. In answer to your question regarding the applicability of Figure D-9 to thirty (30) foot straight ladders, the above statement concerning the requirements of 29 CFR 1910.27(d)(1)(ii) should verify that the illustration would apply to the maximum ladder length permissible with a cage. For your information, I am enclosing 29 CFR 1905, which contains provisions for granting variances to methods and/or operations that do not comply with the OSHA standards but may, in fact, provide equivalent employee protection as required by minimum Federal regulations. If I can be of further assistance, please let me know. Sincerely,
C. R. HOLDER |
|
|

Newsletter
RSS Feeds
Print This Page
Text Size
