Standard Cited:19100147 D04 I The control of hazardous energy (lockout/tagout).

Violation Items
Nr: 311611081 Citation: 01019 Issuance: 03/08/2010 ReportingID: 0524700
Viol Type:Serious NrInstances:1 Contest Date:03/31/2010
Abatement Date:03/11/2010 I Nr Exposed:3 Final Order:
Initial Penalty:5000.00 REC: Emphasis:
Current Penalty:5000.00 Gravity:10 Haz Category:REFINERY



Text For Citation: 01 Item/Group: 019 Hazard: REFINERY

29 CFR 1910.147(d)(4)(i): Lock out or tagout devices were not affixed to each energy isolating device by authorized employees: a.BP-Husky Refining, LLC - Oregon, Ohio: On or about September 10, 2009, the employer did not ensure contractors and operators involved in performing maintenance operations on the Crude 1 furnace burners affixed a lockout device to the natural gas shut off valves for the burner pilot lights. No additional abatement information is needed for this item.