Standard Cited:19100119 E03 I Process safety management of highly hazardous chemicals.

Violation Items
Nr: 311611081 Citation: 01005 Issuance: 03/08/2010 ReportingID: 0524700
Viol Type:Serious NrInstances:9 Contest Date:03/31/2010
Abatement Date:04/19/2010 Nr Exposed:250 Final Order:
Initial Penalty:5000.00 REC: Emphasis:
Current Penalty:5000.00 Gravity:10 Haz Category:REFINERY



Text For Citation: 01 Item/Group: 005 Hazard: REFINERY

29 CFR 1910.119(e)(3)(i): The process hazard analysis did not address the hazards of the process: a.BP-Husky Refining, LLC - Oregon, Ohio: On or about September 10, 2009, the employer did not ensure the process hazard analysis for the naphtha treater furnaces addressed the loss of combustion for the process heater. b.BP-Husky Refining, LLC - Oregon, Ohio: On or about September 10, 2009, the employer did not ensure the process hazard analysis for the Vac Furnace 1 C firebox did not address the loss of combustion for the process heater. c.BP-Husky Refining, LLC - Oregon, Ohio: On or about September 10, 2009, the employer did not ensure the process hazard analysis involving the upper pumparound cooler (PR543576) addressed the lack of a pressure relief device to provide shell side protection. d.BP-Husky Refining, LLC - Oregon, Ohio: On or about September 10, 2009, the employer did not ensure the process hazard analysis involving the lower pumparound cooler (PR543757) addressed the lack of a pressure relief device to provide shell side protection. e.BP-Husky Refining, LLC - Oregon, Ohio: On or about September 10, 2009, the employer did not ensure the porocess hazard analysis involving the primary absorber lean oil coolers (PR543585) addressed the lack of a pressure relief device to provide shell side protection. f.BP-Husky Refining, LLC - Oregon, Ohio: On or about September 10, 2009, the employer did not ensure the process hazed analysis involving the primary absorber lean oil coolers (PR543586) addressed the lack of a pressure relief device to provide shell side protection. g.BP-Husky Refining, LLC - Oregon, Ohio: On or about September 10, 2009, the employer did not ensure the process hazard analysis involving the stripper reboiler condensate pot (PR511134) addressed the lack of a pressure relief device to provide tube side protection. h.BP-Husky Refining, LLC - Oregon, Ohio: On or about September 10, 2009, the employer did not ensure the process hazard analysis involving the stripper steam reboiler (PR543538) addressed the lack of a pressure relief device to provide tube side protection. i.BP-Husky Refining, LLC - Oregon, Ohio: On or about September 10, 2009, the employer did not ensure the process hazard analysis involving the stripper CHGO Reboiler (PR543539) addressed the lack of a pressure relief device to provide tube side protection. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.t,