PROPYLENE GLYCOL
| Method number: |
PV2051 |
| |
| Matrix: |
Air |
| |
| Target concentration: |
25 mg/m3 (8.0 ppm) 100 mg/m3 Ceiling |
| |
| Procedure: |
Samples are collected by drawing a known volume of air through OSHA Versatile Sampler tubes, containing a glass fiber filter (GFF) and two sections of XAD-7 adsorbent (OVS-7). Samples are desorbed with methanol and analyzed by gas chromatography (GC) using a flame ionization detector (FID). |
| |
Recommended air volume and sampling rate: |
60 L at 1.0 L/min (TWA samples) 15 L at 1.0 L/min (ceiling samples) |
| |
| Reliable quantitation limit: |
0.011 ppm (0.035 mg/m3) |
| |
| Status of method: |
Partially Evaluated Method. This method has been subjected to established evaluation procedures, and is presented for information and trial use. |
| |
| Date: February 1999 |
Chemist: Wayne Potter |
Chromatography Team
OSHA Salt Lake Technical Center
Salt Lake City, UT 84115-1802
1. General Discussion
1.1 Background
1.1.1 History
Airborne propylene glycol has been determined by collection on a 37-mm glass fiber
filter in a Swinnex cassette followed by a midget impinger of isopropanol connected in
series and analyzed by gas chromatograph with a flame ionization detector. (Ref. 5.1).
Impingers are difficult for workers to wear and present a possibility of exposure to the
solvent used. NIOSH Method 5523 (Ref. 5.2) uses the XAD-7 OVS tube which
combines a glass fiber filter and XAD-7 resin into one sampler and is also analyzed by
gas chromatography with a flame ionization detector. Method 5523 requires samples to
be packed in dry ice for shipment. One of the advantages of this method is not having
to connect the glass fiber filter and impinger in series. Another advantage is not having
to sample with an impinger and the associated solvent.
The purpose of this study was to evaluate the collection and analysis of propylene glycol
with the OVS-7 tubes at the same level as the ACGIH Ceiling level for ethylene glycol
and to test a 60 L air sample for TWA samples.
1.1.2 Toxic effects (This section is for information only and should not be taken as the basis
of OSHA policy.) (Ref. 5.3)
Taken internally, propylene glycol is harmless, probably because its oxidation yields
pyruvic and acetic acids.
1.1.3 Workplace exposure (Ref. 5.4)
Propylene glycol is used in organic synthesis, especially polypropylene glycol, polyester
resins, cellophane and antifreeze solutions. It is a solvent for fats, oils, waxes, resins,
flavoring extracts, perfumes, colors, softdrink syrups, and antioxidants. Propylene glycol
is also used as a coolant in refrigeration systems. It is used as an emulsifier, food
additive, anticaking agent, solvent, wetting agent, humectant, preservative (retards molds
and fungi), and in cleansing creams, suntan lotions, pharmaceuticals, plasticizers,
hydraulic fluids, brake fluids, bactericide, textile conditioners and deicing fluids for airport
runways.
1.1.4 Physical properties and other descriptive information (Ref. 5.4 unless otherwise
indicated).
| Synonyms: |
1,2-Propanediol, 1,2-dihydroxypropane, methylene glycol, methyl glycol |
| CAS number: |
57-55-6 |
| IMIS: |
P108 |
| RTECS: |
TY2000000 (Ref. 5.5) |
| Molecular weight: |
76.10 |
| Boiling point: |
187.3°C |
| Melting point: |
-60°C |
| Flash point: |
210°F (OC)
|
| Vapor pressure: |
0.05 mm @ 20°C |
| Density: |
1.0381 @ 20°C / 20°C |
| Properties: |
Colorless, viscous, stable, hygroscopic liquid, practically odorless and tasteless. |
| Solubility: |
Miscible with water, alcohol and many organic solvents. |
| Molecular formula: |
C3H8O2 |
| Structural formula: |
|
The analyte air concentrations throughout this method are based on the recommended sampling and analytical parameters. Air concentrations listed in ppm are referenced to 25°C and 101.3 kPa (760 mmHg).
1.2 Limit defining parameters
1.2.1 Detection limit of the overall procedure (DLOP)
The detection limit of the overall procedure is 2.48 µg per sample (0.016 ppm or 0.041
mg/m3). This is the amount of analyte spiked on the sampler that will give a response that
is significantly different from the background response of a sampler blank.
The DLOP is defined as the concentration of analyte that gives a response (YDLOP) that is
significantly different (three standard deviations (SDBR)) from the background response
(YBR).
YDLOP - YBR = 3(SDBR)
The direct measurement of YBR and SDBR in chromatographic methods is typically
inconvenient, and difficult because YBR is usually extremely low. Estimates of these
parameters can be made with data obtained from the analysis of a series of samples
whose responses are in the vicinity of the background response. The regression curve
obtained for a plot of instrument response versus concentration of analyte will usually be
linear. Assuming SDBR and the precision of data about the curve are similar, the standard
error of estimate (SEE) for the regression curve can be substituted for SDBR in the above
equation. The following calculations derive a formula for the DLOP:
| Yobs |
= |
observed response |
| Yest |
= |
estimated response from regression curve |
| n |
= |
total no. of data points |
| k |
= |
2 for a linear regression curve |
At point YDLOP on the regression curve
| YDLOP = A(DLOP) + YBR |
A = analytical sensitivity (slope) |
therefore
Substituting 3(SEE) + YBR for YDLOP gives
The DLOP is measured as mass per sample and expressed as equivalent air
concentrations, based on the recommended sampling parameters. Ten samplers were
spiked with equal descending increments of analyte, such that the lowest sampler loading
was 1.50 µg/sample. This is the amount, when spiked on a sampler, that would produce
a peak approximately 10 times the background response for the sample blank. These
spiked samplers, and the sample blank were analyzed with the recommended analytical
parameters, and the data obtained used to calculate the required parameters (A and SEE)
for the calculation of the DLOP. Values of 532.52 and 111.31 were obtained for A and
SEE respectively. DLOP was calculated to be 0.63 µg/sample (0.003 ppm or 0.010
mg/m3).
Table 1.2.1 Detection Limit of the Overall Procedure
|
mass per sample (µg) |
area counts (µV-s) |
|
0 1.50 3.00 4.49 5.99 7.49 8.99 10.48 11.98 13.48 14.98 |
0 912 1727 2660 3177 4009 4887 5823 6316 7222 8137 |
|
Figure 1.2.1 Plot of data to determine the DLOP/RQL.
1.2.2 Reliable quantitation limit (RQL)
The reliable quantitation limit is 2.09 µg per sample (0.011 ppm or 0.035 mg/m3). This is
the amount of analyte spiked on a sampler that will give a signal that is considered the
lower limit for precise quantitative measurements.
The RQL is considered the lower limit for precise quantitative measurements. It is determined from
the regression line data obtained for the calculation of the DLOP (Section 1.2.1), providing at least 75% of the
analyte is recovered. The RQL is defined as the concentration of analyte that gives a response (YRQL)
such that
YRQL - YBR = 10(SDBR)
therefore
RQL = 2.09 µg per sample (0.011 ppm or 0.035 mg/m3)
The recovery at the RQL is 100%
Figure 1.2.3 Chromatogram of the RQL.
2. Sampling Procedure
2.1 Apparatus
2.1.1 Samples are collected using a personal sampling pump calibrated, with the sampling
device attached, to within ±5% of the recommended flow rate.
2.1.2 Samples are collected using OVS-7
tubes, which are specially made 11-mm i.d. × 13-mm o.d. × 5.0 cm long
glass tubes that taper to 6-mm o.d. ×
2.5 cm. Each tube is packed with a
140-mg back section and a 270-mg
front section of XAD-7 and a 13-mm
diameter glass fiber filter. The back
section is retained by two foam plugs
and the sampling section is between
one foam plug and the glass fiber
filter. The glass fiber filter is held
next to the sampling section by a
polytetrafluoroethylene (PTFE)
retainer. These tubes are commercially available from SKC Inc. (catalog no. 226-57) and
from both Supelco and Forest Biomedical as a custom product.
2.2 Technique
2.2.1 Immediately before sampling, remove the caps from the sampling tubes. All tubes should
be from the same lot.
2.2.2 Attach the small end of the sampling tube to the pump with flexible tubing. Position the
tube so that sampled air passes through the front section (GFF) of the tube first.
2.2.3 Air being sampled should not pass through any hose or tubing before entering the
sampling tube.
2.2.4 Attach the sampler vertically with the open end pointing downward, in the worker's
breathing zone, and positioned so it does not impede work performance or safety.
2.2.5 After sampling for the appropriate time, remove the sample and seal the tube with plastic
end caps. Wrap each sample end-to-end with a Form OSHA-21 seal.
2.2.6 Submit at least one blank sample with each set of samples. Handle the blank sampler in
the same manner as the other samples except draw no air through it.
2.2.7 Record the sample volume (in liters of air) for each sample, along with any potential
interferences.
2.2.8 Ship any bulk samples in separate containers from the air samples.
2.2.9 Submit the samples to the laboratory for analysis as soon as possible after sampling. If delay is unavoidable, store the samples in a refrigerator.
2.3 Extraction and desorption efficiency
The extraction and desorption efficiencies of propylene glycol were determined by liquid-spiking
the 13-mm glass fiber filters and also an amount of XAD-7 adsorbent equal to the adsorbing section
(270 mg) of an OVS-7 tube with the analyte at 0.1 to 2 times the target concentration. The loadings
on the glass fiber filters and the tubes were 149.8, 748.9, 1497.8, and 2995.6 µg of propylene glycol.
These samples were stored overnight at ambient temperature and then desorbed and analyzed by
GC-FID. The average extraction efficiency over the studied range was 99.9% for GFF and 99.4%
for XAD-7.
Table 2.3.1 Extraction Efficiency of Propylene Glycol From GFF
|
| Tube # |
% Recovered |
|
0.1 × 149.8 µg |
0.5 × 748.9 µg |
1.0 × 1497.8 µg |
2.0 × 2995.6 µg |
|
1 2 3 4 5 6
 overall  SD |
100.8 101.9 101.4 100.8 100.6 100.0 100.9 99.9 ± 1.01 |
98.7 97.0 97.9 98.0 99.1 98.8 98.3 |
99.5 100.3 100.8 99.5 100.4 98.2 99.8 |
100.8 101.0 100.3 100.6 100.2 100.4 100.6 |
|
Table 2.3.2 Desorption Efficiency of Propylene Glycol From XAD-7
|
| Tube # |
% Recovered |
|
0.1 × 145.8 µg |
0.5 × 729.1 µg |
1.0 × 1458.2 µg |
2.0 × 2916.4 µg |
|
1 2 3 4 5 6
 overall  SD |
94.0 95.5 95.7 100.0 93.7 97.1 96.0 99.4 ± 2.09 |
99.2 99.1 99.7 99.1 99.6 99.3 99.3 |
101.2 101.7 101.0 101.5 101.1 101.4 101.3 |
98.8 101.9 101.1 100.7 101.9 101.1 100.9 |
|
2.4 Retention efficiency
The glass fiber filter of six sampling tubes was physically separated from the XAD-7 resin beads
and placed on top of the PTFE retainer in each tube to prevent wicking. The glass fiber filters were
spiked with 2995.6 µg (199.7 mg/m3 based on a 15 L air sample) propylene glycol, allowed to
equilibrate overnight at room temperature, and then 60 L humid air (80% RH at 25°C) was drawn
through them at 1.0 L/min. The sampling tubes were opened and the GFF, the front section and
the back section were each put in separate vials. The samples were desorbed and analyzed by
GC-FID. The retention efficiency averaged 100.5%.
Table 2.4 Retention Efficiency of Propylene Glycol
|
| Tube # |
% Recovered |
|
GFF |
Front Section |
Back Section |
Total |
|
1 2 3 4 5 6 |
46.9 33.3 21.0 20.2 19.7 32.7 |
52.2 66.7 78.1 78.0 78.7 65.3 |
1.0 1.6 1.8 1.9 1.9 1.8
 |
100.2 101.6 100.9 100.1 100.3 99.8 100.5 |
|
2.5 Sample storage
The glass fiber filters of twenty-four sampling tubes were each spiked with 1497.8 µg (99.9 mg/m3
based on a 15 L air sample) of propylene glycol. They were sealed and stored at room
temperature. The next day 60 L of humid air (80% RH at 25°C) was drawn through each tube at
1.0 L/min. Half of the tubes were stored in a drawer at ambient temperature and the other half were
stored in a refrigerator at 0°C. After 10 days of storage six samples from the tubes stored under
refrigeration and six samples from ambient storage were analyzed. The remaining samples were
analyzed after 17 days of storage. The average recovery of the ambient and refrigerated storage
samples was 97.2%.
Table 2.5 Storage Test for Propylene Glycol
|
| Ambient Storage |
| |
Refrigerated Storage |
| Time (days) |
% Recovered |
| |
Time (days) |
% Recovered |
|
10 10 10 10 10 10 17 17 17 17 17 17
 |
99.4 98.3 99.3 96.9 99.0 98.0 95.4 95.7 97.0 97.7 95.5 96.9 97.4 |
| | | | | | | | | | | | | |
10 10 10 10 10 10 17 17 17 17 17 17
 |
98.3 97.1 98.1 97.3 96.5 96.4 97.6 94.5 97.1 97.0 96.0 97.9 97.0 |
|
2.6 Recommended air volume and sampling rate.
Based on the data collected in this evaluation, 60 L air samples should be collected at a sampling
rate of 1.0 L/min for TWA samples and 15 L at 1.0 L/min for ceiling samples.
2.7 Interferences (sampling)
2.7.1 It is not known if any compounds will severely interfere with the collection of propylene
glycol on OVS-7 sampling tubes. In general, the presence of other contaminants in the
air will reduce the capacity of the sampling tube to collect propylene glycol.
2.7.2 Suspected interferences should be reported to the laboratory with submitted samples.
2.8 Safety precautions (sampling)
2.8.1 Attach the sampling equipment to the worker in such a manner that it will not interfere with
work performance or safety.
2.8.2 Follow all safety practices of the Chemical Hygiene Plan that apply to the work area being
sampled.
2.8.3 Wear eye protection at all times while in the work areas.
3. Analytical Procedure
3.1 Apparatus
3.1.1 A gas chromatograph equipped with a flame ionization detector. A Hewlett Packard model
5890 was used in this study.
3.1.2 A GC column capable of separating the analyte from any interferences. The column used
in this study was a 30 meter Rtx-35 fused silica capillary column with a 3.0 µm film
thickness and 0.53 mm i.d.
3.1.3 An electronic integrator or some suitable method of measuring peak areas. A Hewlett
Packard model 3396A and the Waters Millennium Data System was used in this study.
3.1.4 Four milliliter vials with TeflonTM-lined caps.
3.1.5 A 10-µL syringe or other convenient size for sample injection.
3.1.6 Pipets for dispensing the desorbing solution. A 2-mL Labindustries dispenser was used
in this study.
3.1.7 Volumetric flasks - 10-mL and other convenient sizes for preparing standards.
3.1.8 A balance for weighing propylene glycol in standard preparation. A Ohaus Galaxy 160D
was used in this evaluation.
3.2 Reagents
3.2.1 GC grade nitrogen, hydrogen and air.
3.2.2 Propylene glycol (CAS 57-55-6), Reagent grade. Eastman, Lot A7A, was used in this
evaluation.
3.2.3 Methanol (CAS 67-56-1), Certified Spectanalyzed grade. Fisher Chemical, Lot 970338,
was used in this evaluation.
3.3 Standard preparation
3.3.1 At least two separate stock standards are prepared by weighing a quantity of propylene
glycol and diluting with methanol. The concentration of these stock standards was
approximately 150.0 mg/mL.
3.3.2 Dilutions of these stock standards were prepared to bracket the samples. The range of
the standards used in this study was from 74.9 to 1497.8 µg/mL.
3.4 Sample preparation
3.4.1 Sample tubes are opened and the front section (GFF and 270 mg adsorbent), and back
section of each tube are placed in separate 4-mL vials. Discard foam plugs.
3.4.2 Each section is desorbed with 2 mL of methanol.
3.4.3 The vials are sealed immediately and allowed to extract/desorb for one hour on a
mechanical rotator or the vials are shaken vigorously by hand several times during the
extraction/desorption time.
3.4.4 Transfer some of the solution from each of the 4-mL vials to smaller glass vials suitable
for an autosampler if necessary.
3.5 Analysis
3.5.1 Gas chromatograph conditions.
| Injection size: |
1 µL |
|
| Flow rates (mL/min) |
|
| Nitrogen (make-up): |
30 |
| Hydrogen (carrier): |
2 |
| Hydrogen (detector): |
40 |
| Air: |
420 |
|
| Temperatures (°C) |
|
| Injector: |
200 |
| Detector: |
275 |
| Column: |
40 isothermal |
| Chromatogram: |
|
 Figure 3.5.1 Chromatogram at the target concentration. |
3.5.2 Peak areas are measured by an integrator or other suitable means.
3.6 Interferences (analytical)
3.6.1 Any compound that produces an FID response and has a similar retention time as the
analyte is a potential interference. If any potential interferences were reported, they
should be considered before samples are desorbed. Generally, chromatographic
conditions can be altered to separate an interference from the analyte. Using the
analytical conditions in this method, ethylene glycol does not interfere.
3.6.2 When necessary, the identity or purity of an analyte peak may be confirmed by a GC-mass spectrometer or by another analytical procedure.
Figure 3.6.2 Mass spectra of propylene glycol.
3.7 Calculations
3.7.1 The calibration curve was made from at least four standards at different concentrations
bracketing the samples.
3.7.2 The values for the samples are obtained from the calibration curve.
3.7.3 To calculate the concentration of analyte in the air sample the following formulas are used:
(µg/mL) (desorption volume) (desorption efficiency) |
= mass of analyte in sample |
(mass of analyte in sample) molecular weight |
= number of moles of analyte |
| ( |
number of moles of analyte |
) |
( |
molar volume at 25°C & 760 mm Hg |
) |
= |
( |
volume the analyte will occupy at 25°C and 760 mm Hg |
) |
(volume analyte occupies) (106)* (air volume) |
= ppm |
* All units must cancel.
3.7.4 The above equations can be consolidated to the following formula.
(µg/mL) (DV) (24.46) (106) (g) (mg) (Liters) (DE) (MW) (1000 mg) (1000 µg) |
= ppm |
| µg/mL |
= |
Concentration of analyte in sample or standard |
| 24.46 |
= |
Molar volume (liters/mole) at 25°C and 760 mm Hg |
| MW |
= |
Molecular weight (g/mole) |
| DV |
= |
Desorption volume |
| Liters |
= |
Liters of air sample |
| DE |
= |
Desorption efficiency |
3.7.5 To calculate the mg/m3 of analyte in the sample based on a 60 liter air volume:
(µg/mL) (DV) (mg) (1000 L) (Liters) (DE) (1000 µg) (m3) |
= mg/m3 |
where:
| µg/mL |
= |
Concentration of analyte in sample or standard |
| DV |
= |
Desorption volume |
| Liters |
= |
Liters of air volume |
| DE |
= |
Desorption efficiency |
3.7.6 This calculation is done for each section of the sampling tube and the results added
together after a blank correction is performed, if necessary.
3.8 Safety precautions
3.8.1 Adhere to the rules set down in your Chemical Hygiene Plan (which is mandated by the
OSHA laboratory standard).
3.8.2 Avoid skin contact and inhalation of all chemicals.
3.8.3 Wear safety glasses, gloves and a lab coat at all times while in the laboratory areas.
4. Recommendations for Further Study
Collection studies should be performed with controlled test atmospheres. This method does not
differentiate between particulate and vapor so more work could be done to find a sampling device that
would do that.
5. References
5.1 Besser, B., OSHA Salt Lake Technical Center, Organic Division In-house file for Propylene Glycol,
Study of Propylene Glycol, May 1983, OSHA SLTC, Salt Lake City, UT.
5.2 National Institute for Occupational Safety and Health: Method No. 5523, Glycols, in NIOSH Manual
of Analytical Methods. 4th ed., Vol. 1, Cincinnati, OH: National Institute for Occupational Safety and
Health, 1996.
5.3 The Merck Index, 12th ed.; Budavari, S., Ed.; Merck & Co., Whitehouse Station, NJ, 1996, p 1349.
5.4 Hawley's Condensed Chemical Dictionary, 12th ed.; Revised by Lewis, R. J.; Van Nostrand
Reinhold: New York, 1993; pp 970-971.
5.5 Sweet, D., "Registry of Toxic Effects of Chemical Substances", 1985-86 ed., U.S. Department of
Health and Human Services, Public Health Service, Center for Disease Control, NIOSH, 1987, Vol.
4, Index Number TY2000000, p.3768.
|