NAME: Ramrod
SYNONYM(s):
Propachlor; Acetamide, 2 Chloro-N-(1-methylethyl)-N-Phenyl;
Bexton, Bexton 4L; CP31393; Niticid; Satecid
IMIS: 2165
CAS: 1918-16-7
NIOSH: RTECS AE1575000; 1384
DESCRIPTION:
Light tan solid.
MW:
212
MP:
67-76 C
Exposure Limits
Health Factors
HEALTH EFFECTS:
Dystrophic changes in liver and kidneys of rats, mice and rabbits
LD50 (rats) 710 mg/kg
Monitoring
PRIMARY SAMPLING/ANALYTICAL METHOD (SLC1):
MEDIA:
Glass Fiber Filter (37 mm)
ANL SOLVENT:
Acetonitrile
MAX V:
120 Liters MAX F:
1.0 L/min
ANL 1:
High Performance Liquid Chromatography; HPLC/U.
REF:
2 (OSHA In-House File)
CLASS:
Partially Validated
COND:
Zorbax ODS column; 50% acetonitrile 50% water; 1 mL/min;
UV det: 214 nm; 254 nm; DL 0.5 ug/sample
BULK METHOD:
Limit the amount of bulk submitted to one gram or one mL.
|