Chemical Sampling Information
Linuron
 Field Definitions
 Analytical Methods
General Description

NAME: Linuron

SYNONYM(s): N'-(3,4-Dichlorophenyl)-N-methoxy-N-methyl urea; Afalon; Linurex; Lorox

IMIS: L128

CAS: 330-55-2

NIOSH: RTECS YS9100000; 86417

DESCRIPTION:


MP: 93-94 C
VP: 1.5 x 10-5 mm at 24 C



Exposure Limits


Health Factors

HEALTH EFFECTS: LD50 (oral, rat) 1500 mg/kg

Monitoring

PRIMARY SAMPLING/ANALYTICAL METHOD (SLC1):



MEDIA: Glass Fiber Filter (37 mm)
MAX V: 240 Liters   MAX F: 1.0 L/min
ANL 1: High Performance Liquid Chromatography; HPLC/U.
REF: 2 (OSHA In-House File)
CLASS: Not Validated

COND: Chloroform extraction; C18 column; 55% methanol 45% water; 2 mL/min; UV Det: 254; Retention time, 12.7 min; DL 0.2 ug/sample; C/P DBA

WIPE:

Yes, Glass fiber filter.

BULK METHOD:

Limit the amount of bulk submitted to one gram or one mL.


Revision Date: 08/24/1992