OSHA IMIS Code Number: V119
Chemical Abstracts Service (CAS) Registry Number: 1321-74-0
Other Chemical Abstracts Service (CAS) Registry Number: 108-57-6
NIOSH Registry of Toxic Effects (RTECS) Identification Number: CZ9450000; 13902
American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value (TLV): 10 ppm, 53 mg/m3 TWA
National Institute for Occupational Safety and Health (NIOSH) Recommended Exposure Limit (REL): 10 ppm TWA
Primary Laboratory Sampling/Analytical Method (SLC1):
- sampling media: Coated Charcoal Tube (100/50 mg sections, 20/40 mesh) Coating is p-tert-butylcatechol.
analytical solvent: Toluene
maximum volume: 12 Liters
maximum flow rate: 0.05 L/min
current analytical method: Gas Chromatography; GC/FID
method reference: 2 (OSHA 89)
sampling and analytical error: 0.08
method classification: Fully Validated