tert-Butyl Acetate
Synonyms: tert-Butyl ester of acetic acid
OSHA IMIS Code Number: 0442
Chemical Abstracts Service (CAS) Registry Number: 540-88-5
NIOSH Registry of Toxic Effects (RTECS) Identification Number: AF7400000
Department of Transportation Regulation Number (49 CFR 172.101) and Guide: 1123 129
NIOSH Pocket Guide to Chemical Hazards, tert-Butyl Acetate: chemical description, physical properties, potentially hazardous incompatibilities, and more
OSHA Permissible Exposure Limit (PEL):
General Industry: 29 CFR 1910.1000 Z-1 Table -- 200 ppm, 950 mg/m3 TWA
Construction Industry: 29 CFR 1926.55 Appendix A -- 200 ppm, 950 mg/m3 TWA
Maritime: 29 CFR 1915.1000 Table Z-Shipyards -- 200 ppm, 950 mg/m3 TWA
American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value (TLV): 200 ppm, 950 mg/m3 TWA
National Institute for Occupational Safety and Health (NIOSH) Recommended Exposure Limit (REL): 200 ppm, 950 mg/m3 TWA
NIOSH Immediately Dangerous To Life or Health Concentration (IDLH): 1,500 ppm [LEL]
Potential Symptoms: Itching, inflamed eyes; irritated upper respiratory system; headaches; narcosis; dermatitis
Health Effects: Irritation-Eye, Nose, Throat---Moderate (HE15); Narcosis (HE8)
Affected Organs: Respiratory system, eyes, skin
Laboratory Sampling/Analytical Method:
- sampling media: Charcoal Tube (100/50 mg sections, 20/40 mesh)
analytical solvent: Carbon Disulfide
maximum volume: 12 Liters maximum flow rate:0.05 L/min (TWA)
maximum volume: 0.75 Liters maximum flow rate:0.05 L/min (STEL)
current analytical method: Gas Chromatography; GC/FID
method reference: OSHA Analytical Method (OSHA 1009)
method classification: Fully Validated
- sampling media: Diffusive Sampler:
- 3M 3520 Organic Vapor Monitor;
- SKC 575-002 Passive Sampler
analytical solvent: Carbon Disulfide
minimum time: 15 to 240 Minutes
current analytical method: Gas Chromatography; GC/FID
method reference: OSHA Analytical Method (OSHA 1009)
method classification: Fully Validated
note: Persons using diffusive samplers to monitor workplace air must ensure that the sampling devices are properly closed before transporting such devices to the laboratory for analysis. The device will continue to sample until properly closed. Diffusive sampler accessories used for analysis of samplers must be included with transported samples. Persons using such devices must provide sampling-site station barometric pressure and temperature to the analytical laboratory to improve accuracy of sampling results.
- sampling media: Charcoal Tube (100/50 mg sections, 20/40 mesh)
analytical solvent: Carbon Disulfide
alternate analytical solvent(99:1) Carbon Disulfide:Dimethylformamide
maximum volume: 10 Liters maximum flow rate:0.2 L/min
current analytical method: Gas Chromatography; GC/FID
method reference: NIOSH Analytical Method (NIOSH 1450 [107 KB PDF, 6 pages])
method classification: Fully Validated
note: Samples should be refrigerated as soon as possible after sampling and sent cold to the laboratory.