OSHA IMIS Code Number: 0376
Chemical Abstracts Service (CAS) Registry Number: 12179-04-3
Chemical Description and Physical Properties:
American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value (TLV): 1 mg/m3 TWA
National Institute for Occupational Safety and Health (NIOSH) Recommended Exposure Limit (REL): 1 mg/m3 TWA
Health Effects: Irritation-Eye, Nose, Throat, Skin---Moderate (HE15)
Laboratory Sampling/Analytical Method:
- sampling media: Tared Low Ash Polyvinyl Chloride (LAPVC) filter 5 microns
maximum volume: 960 Liters
minimum volume: 480 Liters
maximum flow rate: 2.0 L/min
current analytical method: Inductively Coupled Argon Plasma; ICP/DCP-AES
method reference: 2 (OSHA ID-125G)
method classification: Not Validated
note: Submit as a separate sample only if the gross weight of the sample yields an air concentration greater than the PEL. When analysis of this compound is requested, an elemental analysis for Boron is performed and reported as the compound. Procedure based on OSHA method ID-125G.
Wipe Sampling Method
-
sampling media: Whatman smear tab
analytical solvent: Deionized water
** All Trademarks are the property of their respective owners.