Chemical Sampling Information
Benzo (e) Pyrene |
Chemical Sampling Information - Table of Contents |
Field Definitions
Analytical Methods
|
NAME: Benzo (e) Pyrene
IMIS: B129
CAS: 192-97-2
NIOSH: RTECS DJ42000000; 18285
Exposure Limits
OSHA GENERAL INDUSTRY PEL: See Coal Tar Pitch Volatiles (Benzene Soluble Fraction)
Health Factors
IARC: Group 3, not classifiable as to its carcinogenicity to humans
Monitoring
PRIMARY SAMPLING/ANALYTICAL METHOD (SLC1):
MEDIA: Glass Fiber Filter (37 mm)
MAX V: 960 Liters MAX F: 2.0 L/min
ANL 1: High Performance Liquid Chromatography; HPLC/U.
REF: 2 (OSHA In-House File)
CLASS: Not Validated
NOTE: After sampling, filter must be transferred to a glass vial with a Teflon-lined cap. The sample must be protected from direct sunlight.
COND: Column: C18 Mobile Phase: 85.15 Acetonitrile: Water Detector Wavelength: 254nm or 254 EX: 370 EM (Fluor) Detection Limit:
|
Chemical Sampling Information - Table of Contents
|
Revision Date: 08/24/1992
* All Trademarks are the property of their respective owners.