OSHA IMIS Code Number: A257
Chemical Abstracts Service (CAS) Registry Number: 37293-45-1
Primary Laboratory Sampling/Analytical Method (SLC1):
- sampling media: Glass Fiber Filter (37 mm)
maximum volume: 200 Liters
maximum flow rate: 1.0 L/min
current analytical method: High Performance Liquid Chromatography; HPLC/U
method reference: 2 (OSHA In-house File)
method classification: Not Validated
Conditions: Mobile phase extraction; C18 column; 73% methanol 27% water, PIC A 1 mL/min; UV det: 254, 280; 3 ug/sample; ext. eff. 96%
Wipe Sampling Method:
-
sampling media: Glass Fiber Filter (HPLC/UV)
Bulk Method:
- For any dye analysis, a bulk sample of the dye must be sent to the Salt Lake Technical Center. Limit the amount of bulk submitted to one gram or approx. one mL.
** All Trademarks are the property of their respective owners.