    TEXT VERSION OF SLIDE:

    Title: Maximum Use Concentration Example
    Type: Text Slide
    Content:

    What is the MUC for an employee wearing a half-mask air purifying respirator (APF=10) in an atmosphere of sulfur dioxide gas (PEL=5 ppm)?

    MUC = APF x OSHA Exposure Limit

    MUC = 10 x 5 ppm = 50 ppm

    Note that this calculated value does not exceed the IDLH level for sulfur dioxide (100 ppm), so that the MUC for this example would be 50 ppm.
 
 