Device Fabrication: Photoresist Application
Following the creation of a silicon dioxide layer, the wafer is coated with a photosensitive material called a "photoresist." 
  • There are two types of photoresists: positive and negative. Positive photoresists undergo weakening when exposed to irradiation, whereas negative photoresists are strengthened. Most semiconductor processes use a positive resist.
  • The photoresist is applied by delivering a small amount of the liquid to the center of the wafer, then spinning the wafer at high speed to spread the material over the entire surface in a thin, uniform coating. Sometimes wafers are primed with an adhesive, hexamethyldisilazane (HMDS). Glycol ethers have been a popular solvent for carrying HMDS, although some manufacturers have switched to alternative solvents like xylene, n-butyl acetate, acetone, and 1,1,1-trichloroethane. Table 1 identifies the component makeup of various photoresist systems.
Potential Hazards
Photoresist Chemicals
Potential Hazard
  • Possible employee exposure to photoresist chemicals (see Table 1).
Possible Solutions
  • Identify chemical hazards and perform appropriate exposure evaluations.

    • Perform exposure measurements for the chemicals used.

    • See 1910.1000, Table Z-1, which contains permissible exposure limits for various chemicals.
  • Address all dermal exposures.

  • Provide appropriate ventilation to reduce chemical concentration levels in the air.

  • Provide PPE [1910 Subpart I] as appropriate to prevent eye and skin contact.

  • Use respiratory protection [1910.134] when necessary to further reduce exposure and protect employees.

  • Design and use specialized processing, material handling, and storage equipment to properly contain chemicals. Consider both normal use and emergency scenarios.

  • Install emergency facilities to provide immediate treatment in the event of an accidental exposure to corrosive materials. According to 1910.151, provide suitable facilities for quick drenching or flushing of the eyes and body for immediate emergency use whenever the eyes or body may be exposed to corrosive materials.
Additional Information

OSHA Safety and Health Topic pages:


Solvents
Potential Hazard
  • Possible employee exposure to solvents used for adhesive application.

    • Glycol ethers have been a popular solvent. However, due to reproductive effects associated with exposures, they have been replaced with other chemicals.

    • Replacement solvents for glycol ethers have included chemicals such as xylene, n-butyl acetate, acetone, and 1,1,1-trichloroethane.
Possible Solutions Additional Information
  • Xylene. OSHA Health Guidelines page.

 