A Suggested Air Sampling Strategy for Microorganisms in Office Settings GEORGE K. MORRIS, PH.D. AND BRIAN G. SHELTON, M.P.H. PathCon Laboratories, Norcross, Georgia 30092 The American Conference of Governmental Industrial Hygienists developed the manual - "Guidelines for the Assessment of Bioaerosols in the Indoor Environment" (ACGIH, 1989) - to address the increasing need for indoor air quality investigations, including the analysis of bioaerosols. This manual was intended to be a guide for investigating building-related complaints that might be caused by viable airborne organisms or their effluents. There are no governmental or industrial guidelines as to acceptable levels of microorganisms in indoor air. PathCon has developed this Technical Bulletin (2.4) to describe our specific methods for analyzing air samples for fungi and bacteria. The air sampling protocols, which are consistent with the ACGIH Guidelines, were designed to yield microbiological data in order to assist the on-site investigator in making valid interpretations about the amplification of bacteria and fungi associated with indoor environmental sources. This Technical Bulletin includes 2 protocols: the 7-plate protocol and the 4-plate protocol. The samples should be collected by a trained environmental health professional with experience in sampling for microorganisms; therefore, this protocol is not a complete sampling guide. PathCon Laboratories does not assume responsibility for selection of the appropriate sampling protocol or interpretation of the findings. These decisions must be made by the on-site investigator. SEVEN-PLATE PROTOCOL SAMPLE COLLECTION This protocol utilizes seven plates of microbiological media. The sampling is done with an impaction-type sampler. The samplers most often used by PathCon clients are the SAS (Surface Air System) sampler and the Andersen N6 sampler. They are calibrated before and after each job. For the interpretation of microbiological findings, air samples must be taken at an outdoor site (preferably at the outdoor air intake of the building) and at appropriate indoor sites. The indoor sites should include those areas associated with occupant complaints and, if possible, at least one area not associated with occupant complaints. It is strongly recommended that samples at each air site be taken at multiple times during the day (i.e., morning and afternoon or at intervals at least 2 hours apart). The set of 7 plates must be exposed at each sampling site as follows:
Instructions for sample collection and forms for sample identification will be provided by the laboratory. For the quantification of bacteria and fungi in air, it is required that the sampler be calibrated to provide an accurate measurement of flow rate. The paired plates 1 and 4, plates 2 and 5. and plates 3 and 6 are each evaluated as sets to determine the number of organisms per cubic meter of air and for selecting predominant microbial taxa for identification.
FOUR-PLATE PROTOCOL SAMPLE COLLECTION The four-plate protocol is designed for those investigators who want to analyze for fungi and environmental bacteria only. It utilizes two types of microbiological media. The two media are Rose Bengal Agar (or Malt Extract Agar) for the fungal analysis and R2Ac Agar for the environmental bacterial analysis. The total sample exposure time is 3 minutes for each type of media divided among the plates as shown in Table 2. The four-plate protocol may be used in place of the seven-plate protocol when data on human commensal and thermophilic bacteria is not required. PathCon technical staff members are available for phone consultation with clients. We offer assistance to the on-site investigator in developing an appropriate air sampling strategy suited to each specific situation. However, the final decision on sampling strategy must be made by the on-site investigator.
ANALYZING DATA When the 7-plate protocol is implemented, results are obtained as described below. The 4-plate protocol yields data on fungi and environmental bacteria only.
By comparing the microbiological profiles at the sites associated with health complaints to those at sites associated with no health complaints - and to those at the outdoor air sites - it may be possible to determine if amplification of microorganisms is occurring at the indoor air sites in buildings. Fungal amplification should be considered when the indoor concentration is above 200 colony forming units per cubic meter of air and substantially exceeds that detected in the outdoor air. Selective fungal amplification may exist when specific fungal taxa that are absent or in low numbers in the outdoor air are found in substantially higher numbers in the indoor air. Bacterial amplifcation should be considered only for environmental-type bacteria and not human commensals. Amplification should be considered only when counts are above 200 and substantially exceed other sites within the building and/or that found in the outdoor air. An increase in the concentration of human shed bacteria is expected over the work day. Increased numbers of human commensal bacteria at indoor sites may indicate high occupant density and/or poor ventilation. Samples are screened for potential pathogens such as Aspergillus fumigatus, Pseudomonas aeruginosa, Staphyloccuraureus, etc. The analytical results from water and other bulk samples collected from building systems have much greater value if they can be related to amplification of microorganisms in air. ANALYTICAL LIMITATIONS There are no governmental or industrial regulations concerning permissible levels of fungi and bacteria in indoor air. The protocols described here are designed to detect abnormal microbiological amplification. The purpose is not to suggest associations with health complaints in building occupants nor to suggest any remediation procedures. The protocols are suggested to assist the on-site investigator in developing a strategy for overall assessment. Decisions regarding the selection of protocol and overall interpretation of findings must be made by the on-site investigator. In determining the existence and source of microbial amplification in a building, visible evidence of microbial contamination must weigh heavily on the decision. Air sampling represents a "snapshot in time". In order to make a good interpretation of microbiological air sampling data, it is strongly recommended that air sampling be done at multiple times. If the multiple sampling must be done in a single day, we suggest that separate samples be taken in the morning and afternoon at intervals at least 2 hours apart. A negative result does not indicate that the source of the sample was free of fungi or bacteria. A negative result indicates only that if present in the sample, the number of fungi or bacteria was below the detection limits of the test. ©Copyright 1994 Pathogen Control Associates, Inc. 270 Scientific Drive Suite 3 Norcross, Georgia 30092 Phone: 770-446-0540 Fax: 770-446-0610 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||