Oxide Drum Filling Local Exhaust Ventilation
Oxide Drum Filling
Text Version

Oxide Drum Filling Local Exhaust Ventilation

Oxide drum with drum filling tube, plenum, perforated plate (50% open) or slotted plate (size slot for 2000 fpm), flare fill tube, and flexible tubing to fan or main with 45% take-off. A schematic view is also included.

Design Criteria:

Q = 600 cfm
Vt = 4,500 fpm
he = 1.78 VPslot + 0.25 VPduct